– Motor protection switch transport has tripped Water entrainment by washware Phase missing on feed cable, motor protection switch or contactor Heater defective If the temperature falls short of tempe- rature F14 for a time >= C06, the fault message is displayed and transport is stopped! If tank filling is not completed within C38, the fault message is displayed.
#Angelo po service manual manual#
Spray nozzle has dropped from rinse arm Wrong diaphragm installed or setting of manual valve changed Phase missing on feed cable, motor protection switch or contactor Heater defective If the temperature falls short of tempe- rature F15 for a time >= C06, the fault message is displayed. Hot water tank heater contactor defective If at fill start the temperature F01 is not reached within time C37, the fault mes- sage is displayed. Rinse arm not in position Leak in final rinse system Leak O-ring rinse arm holderįill start temperature hot water tank not reached On site shut-off valve not completely open If the fault lasts longer than C01, Err 001 is generated! Display changes to RED/ DURATION If the response time of the float switch > C02, the fault message is displayed. If the float switch has already switched for the first time (= break tank was full), the switching hysteresis is from now If the solenoid valve is actuated for the first time after "Machine on", the time until the float switch 1B1 responds is measured – if this time exceeds the preset time C01, the fault message is displayed.įilter or reducer upstream of solenoid valve clogged